Hydraulics hose SAE J517 100R2AT Size (Inch) Inside Diameter Reinforcement Outside Diameter Proof Pressure Working Pressure Burst Pressure Bend Radius Nom (mm) Min (mm) Max (mm) Min (mm) Max (mm) Min (mm) Max (mm) (Bar) (Psi) (Bar) (Psi) (Bar)
SAE 100R4 hose should be used in low pressure and vacuum appliions, with petroleum- and water-based hydraulic fluids, within a temperature range from140 to 100 C. It is constructed with an inner tube of oil-resistant synthetic rubber, a reinforcement consisting of a ply, or plies, of woven or braided textile fibers with a suitable spiral of body wire, and an oil- and weather-resistant
Hose SAE J1402 Al Air Brake Hose SAE J1402 A Liquefied Petroleum Gas SAE J2064 TYPE C Push-Lok Hose Outer Diameter A critical measurement when considering hose clamps and appliions where envelope size is limited. Minimum Bend Radius
diameter. For our example use 7/16" Next measure the threads per inch – use 20. Our fitting size measures 7/16-20. Refer to the thread SPECIALTY HOSE HIGH PRESSURE HOSE LOW & MEDIUM PRESSURE HOSE APPLIION DA TA See page it is
For example, Parker Hannifin’s Hose Products Division offers hydraulic hoses with one-half the minimum bend radius outlined in SAE standards at full SAE pressure. For example, the bend radius of Parker’s 797 hydraulic hose is half of SAE’s 100R1, 100R2, 100R4, 100R12, and 100R13 minimum requirement, which reduces hose length requirements by up to 47%.
All pressure ratings are shown in PSI (pounds per square inch). SAE J1926-1 SAE J1453 SAE J518 OBR ORFS CODE 61 CODE 62 Dash Size Nominal Tube/Port Size (inches) SAE 100R2 Male Male Adj. Male Swivel Flange Flange 04 1 / 4
Size The hose I.D. must be sized accurately to obtain the proper flow velocity. A flow that’s too slow results in sluggish system performance and a flow that’s too high causes excessive pressure drops, system damage, and leaks. Use the Flow Capacity Nomogram to determine the proper hose I.D. for your appliion’s flow rate requirements.
HOSE ASSELIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE SAE Flange alogue [ I ] SAE-Flansche (ISO 6162)
Hydraulic hose end fittings to suit DIN and SAE spec hoses plus an extensive range of adapters for various pressure ratings. Outer Diameter of Tube Design Working Pressure Proof Pressure Over Pressure mm ins BAR psi BAR psi BAR psi 4.7 3/16 303.4
Hydraulic hose end fittings to suit DIN and SAE spec hoses plus an extensive range of adapters for various pressure ratings. Outer Diameter of Tube Design Working Pressure Proof Pressure Over Pressure mm ins BAR psi BAR psi BAR psi 4.7 3/16 303.4
1/2 to 1 inch Hose Inside Diameter : 1/2 to 1 inch 0 to 25 mm Hose Inside Diameter : 0 to 25 mm Parker''s Pipe Fittings and Port Adapters product line offers a wide range of thread types and high static pressure ratings. 1946 Parts Viewing 10 of 1946 Close
Inner diameter (I.D.) is the span of the empty space in a circular hose cross-section that affects the flow velocity of the fluid within the hose. A hose with an oversized I.D. will result in sluggish system performance, while an undersized I.D. can cause excessive pressure drops, leaks, and system damage.
Inner diameter (I.D.) is the span of the empty space in a circular hose cross-section that affects the flow velocity of the fluid within the hose. A hose with an oversized I.D. will result in sluggish system performance, while an undersized I.D. can cause excessive pressure drops, leaks, and system damage.
SAE 100R15 high pressure hydraulic hose is reinforced by four or six alternating layers of spiral and high tensile steel wires. It is very popular in logging, construction, mining, agriculture and oil field equipment, because it can work constantly under high pressure.
Size Parker uses a system of measurement called Dash Nuers to indie hose and fitting size. The Dash Nuer, or Dash Size, is the measure of a hose’s Inner Diameter (I.D.) in sixteenths of an inch. (The exception to this is SAE 100R5 hose. See the chart
JGB presents the J-FLEX SAE Hydraulic Hoses. MSHA approved. Blue cover available. J-FLEX 1 1SN/SAE 100R1AT, J-FLEX 2M 2SN/SAE 100R2AT, J-FLEX 12M SAE 100R12, J-FLEX 13M SAE 100R13, J-FLEX 15M SAE 100R15. Request a quote. Hose ID
Hose SAE J1402 Al Air Brake Hose SAE J1402 A Liquefied Petroleum Gas SAE J2064 TYPE C Push-Lok Hose Outer Diameter A critical measurement when considering hose clamps and appliions where envelope size is limited. Minimum Bend Radius
SAE BOSS Fitting O-ring Ports are the preferred port connection for use in hydraulic systems on industrial equipment and commercial products. The adjustable O-ring fittings described in this section provide a variety of options for connections between tube, hose and pipe ends.
E-5 Hose Products Division Parker Hannifin Corporation Wickliffe, Ohio alog 4400 US Technical A B C Equipment D Accessories E Technical Hose Fittings Temperature / Pressure Chart - 201, 206, 213, and 266 Hose Example: 201-8 hose
First Hose Ltd is a leading provider of offshore rig supply hoses, hydraulic hoses, instrumentation, adapters and fittings to the oil and gas industry. Outer Diameter of Tube Design Working Pressure Proof Pressure Over Pressure mm ins BAR psi BAR psi BAR psi 4.7
Tube Pressure Ratings Applicable to SWEPTS Only – Not Applicable to PUSH-IN SWEPTS Outer Diameter of Tube Design Working Pressure Proof Pressure Over Pressure mm ins BAR psi BAR psi BAR psi 4.7 3/16 303.4 4400 455 6600 910 13200 6.3 1/4 391
1) Threads per SAE J475 Class 2A ext. Class 2B int. (Ref. ISO-263/lSO-R725) 2) Unified class 2B threads apply to swivel nuts and with minor diameter modified to class 3B limits for locknuts Pressure Ratings for Fittings With NPTF Pipe Threads and Adapter-20
Parker Hose Products Division has a full line of hydraulic hoses designed for one-half SAE bend radius at full SAE pressure, which exceeds the minimum bend radius. For example, the bend radius of Parker’s 797 hydraulic hose is half of SAE’s 100R1, 100R2, 100R4, 100R12 and 100R13 minimum requirement, which reduces hose length requirements by up to 47%.
Size The hose I.D. must be sized accurately to obtain the proper flow velocity. A flow that’s too slow results in sluggish system performance and a flow that’s too high causes excessive pressure drops, system damage, and leaks. Use the Flow Capacity Nomogram to determine the proper hose I.D. for your appliion’s flow rate requirements.
SAE 37O JIC THREAD connects to external threads DASH NO. THREAD SIZE STYLE PART NUER FITTING THREAD SAE 37O MALE MAJOR DIAMETER LENGTH RATED PRESSURE FACE SEAL REPLACEMENT SEALS, 5 PACK-4 (7/16-20) Connector
Parker Parflex H580N Hose High Pressure Hose 2000 to 5000 PSI Range 2000 to 5000 PSI Pressure Range Meets or Exceeds 100R9 Reinforcement: Fiber Cover: Nylon Specs: SAE 100R8 Parker Parflex 588N Hose High Pressure, Non-Conductive Hose : Fiber
Parker Parflex H580N Hose High Pressure Hose 2000 to 5000 PSI Range 2000 to 5000 PSI Pressure Range Meets or Exceeds 100R9 Reinforcement: Fiber Cover: Nylon Specs: SAE 100R8 Parker Parflex 588N Hose High Pressure, Non-Conductive Hose : Fiber